How Much Heat Will a Grate Heater Put Out?
Share
A Hasty Heat grate heater sits in the fire and blows heated air back into the room. That’s more of the fire’s heat put to use in the house: warm air delivered on top of the glow you already feel through the open doors.
An open fireplace is an air leak, and a good share of the fire’s heat rides that draft up the flue. The heater catches part of it and sends it home. The numbers in this article are that recovered heat, estimated from the physics for each model, with a typical figure and a range from a small fire to a big one.
The short answer
On a normal three-log fire with the blower running, our science-based estimates are:
| Heater | Typical fire | Small fire to big hot fire |
|---|---|---|
| HTH Hard Times Heater (one unit) | about 2,500–5,000 BTU/h (about 0.8–1.5 kW) | about 900–7,500 BTU/h |
| HTH5 Large Hard Times Heater (one unit) | about 3,000–6,000 BTU/h (about 0.9–1.8 kW) | about 1,100–9,000 BTU/h |
| Four 20HTH20D units side by side on one fire | about 12,000 BTU/h (about 3.5 kW) | about 4,000–22,000 BTU/h |
| GR / TGR, 14” to 36” wide (7–18 tubes) | about 8,000–25,000 BTU/h (about 2.3–7.4 kW) | about 3,000–29,500 BTU/h |
| DGR double row, 14” to 36” wide (13–35 tubes) | about 10,500–34,000 BTU/h (about 3.1–10.0 kW) | about 4,000–45,500 BTU/h |
The standard 20HTH20D, our common Hard Times Heater size, is about 4,300 BTU/h on a typical fire (1,500–6,500 BTU/h, or about 0.4–1.9 kW). A 20GR16TD, a mid-size straight grate, is about 11,800 BTU/h on a typical fire (4,600–15,200). For scale, a small plug-in space heater on high is about 5,100 BTU/h (1.5 kW).
Every model and PLU has its own line in the reference table below. Your results vary with fire size, wood, draft, spacing, and fan speed; figures are estimates, not test results.
Two rules before any of these numbers apply
1. Fireplace doors open. For every heater in this table, the fireplace’s glass doors must be open while it runs. These estimates do not apply behind closed doors.
The exception is our Q cube insert line, made for use with glass doors: the 201Q and the 243Q, among other Q sizes. The Q line is not covered by these estimates.
2. It has to fit through the opening. Pick a model that fits through your fireplace opening and sits inside the firebox, not just one that matches the firebox floor. Measure the opening width and height as well as the firebox depth and back width. Our fireplace dimensions guide shows how.
A heater that’s too big won’t go in. One that’s far too small leaves the fire burning beside it instead of on it. Open doors, a snug fit, and the fire does the rest of it.
How we got these numbers
We work the physics of the fire, the steel and the airflow, with the assumptions stated below, and we give each model a typical figure plus a range. The fire itself moves around: the logs, the coal bed, the draft and the wood all change from hour to hour and from house to house, so a range is the honest way to report the heat the heater adds.
An open fireplace on its own puts about 10% of the wood’s heat into the room. Most of the rest goes up the flue. A grate heater catches part of that and blows it back as heated air. With our estimates, a fireplace plus a grate heater lands at about 15–35% overall. That’s more of the fire’s heat in the room, and it’s still well below the heat that’s in the wood, which it has to be.
How we estimate it: Q = 1.08 × cfm × ΔT
The heat the heater blows into the room is:
Q = 1.08 × cfm × ΔT
- cfm is the airflow through the tubes, in cubic feet per minute.
- ΔT is how many degrees Fahrenheit hotter that air is when it comes out than when it went in. We start from room air at about 65 °F.
- 1.08 is the standard air factor that turns airflow and temperature rise into BTU per hour.
- Q is the heat delivered, in BTU/h.
We build the number up, one step at a time, from a single tube.
1. One TD tube. The GR, TGR and DGR use 1” round tubes (the “TD” tubes). For a given airflow through one tube, the temperature rise tells us how much heat that tube can hand to the air. The fire heats the steel by radiation (the glow you feel on your face) and by hot gases washing over the tube. Darkened, seasoned steel absorbs most of that radiation. We also account for how much of the fire each tube can actually “see,” because tubes packed side by side shade each other, and flames come and go.
2. A manifold section. A 120 mm AC fan, with a published rating of 110 cfm, feeds a set of those tubes. The air that actually moves through the tubes is always less than the box rating, because the tubes add resistance. That airflow is shared across the tubes in the section.
Fan counts, now confirmed: the 14” to 24” GR and TGR use one fan. The 30” and 36” GR and TGR use two fans on one shared plenum. The DGR uses one fan on the 14” and 16” sizes, two on the 20” and 24”, and three on the 30” and 36”.
3. Tube count. A 14” GR has 7 tubes; a 36” GR has 18. The TGR uses the same tube counts, tapered to follow a firebox that’s wider in front than in back. The DGR doubles up, with 13 to 35 tubes. More tubes mean more heat, and the wider sizes add fans so the extra tubes still get air. A fire only has so much heat to give, so the total still stays within a reasonable share of the fire.
4. The HTH, the same way. The Hard Times Heater is simpler. Each unit is one larger rectangular tube (4x2 on the HTH, 5x2 on the HTH5) with its own fan, so you don’t share a fan across a row. We still use Q = 1.08 × cfm × ΔT, with the airflow that fan can actually push through that tube. Add a second or third unit and you add more of that heat, minus a little, because they share one fire.
A few more bounds keep the numbers honest:
- We cap the steel below the temperature where it would start to glow red (about 950 °F). The heaters aren’t meant to run that hot, and the cap keeps the estimate conservative.
- Heat also travels through the steel wall and around to the sides that don’t face the fire. Heavier steel, like the HTH5, takes a little longer to warm up and keeps giving heat longer after the fire burns down. We include both.
- We limit the total so that no heater claims more than a reasonable share of the fire’s heat.
- Then we check the totals against published fireplace figures, so the whole-fireplace picture stays in a believable band.
Low, typical and high mean a small or settling fire, a normal three-log fire, and a big hot fire you’re tending. We picture three seasoned hardwood logs, 16–20” long and about 4–6” thick, burning roughly 6 to 17 pounds an hour on a 20”-wide grate (about 40,000 to 120,000 BTU/h of fire). Wider fireplaces get proportionally bigger fires. Seasoned hardwood at under 20% moisture, red oak as the example.
Fan off: air still rises through hot tubes on its own. We estimate roughly a third of the blower-on heat. The product pages say roughly a fifth for the HTH5; treat either as a rough guide. It’s useful when the power’s out, but the blower is what makes these heaters work. The HTH’s USB fan is tested to run for 10 hours on a common cellphone battery bank, or even longer on a 12V car battery.
If you ever measure your own, we’d love to see the numbers. A cooking thermometer at the air outlet and a simple anemometer for the airflow are enough: heat ≈ 1.08 × cfm × (outlet temperature − room temperature in °F).
The assumptions behind the numbers
These are science-based estimates, not lab ratings and not test results. Nothing here has been measured on a Hasty Heat unit yet. Overall confidence is medium-low to medium: the numbers are physically bounded, and they check out against published fireplace data, but a real measurement would tighten them.
In plain terms, here’s what we know and what we don’t:
- The HTH and HTH5 sit at medium confidence, with a realistic band of about ±40%. The geometry is simple, and the HTH’s outlet temperature is in line with what customers describe. The owner has approved this HTH model. The fans are still a class assumption: about 65 cfm for the HTH’s 5V 90 mm USB fan, and about 90 cfm for the HTH5’s 12V 120 mm fan, until the datasheets are in hand.
- Several HTHs on one fire sit a little lower (about ±50%), because how they shade each other is a judgment call, and a fourth versus a fifth unit depends on how wide the fire is.
- The GR and TGR sit at medium-low, roughly −50% to +50%. Output is mostly set by airflow through 7–18 small tubes. The ranking between sizes is tighter, good to about ±15%. The TGR is modelled the same as the GR of the same front width (same tubes, manifold and fan count). In a tapered firebox the TGR probably sits better in the fire, but we don’t have a measured difference, so we don’t claim one.
- The DGR sits at medium-low, roughly −45% to +50%. Fire depletion matters most on the biggest sizes.
- The confirmed GR/TGR/DGR fan is a 120 mm, 110 cfm AC fan. Only the two published endpoints are available, so the model uses a straight line between them. Fan counts are confirmed: one fan on 14” to 24” GR and TGR, two fans on 30” and 36” GR and TGR, and on the DGR one fan (14” and 16”), two fans (20” and 24”), or three fans (30” and 36”).
- The Q, DS and RC lines are not in this table. The Q line is the one used with glass doors. DS and RC aren’t modelled yet.
The biggest swings in the estimate, largest first: the actual airflow through the tubes; the 950 °F wall-temperature cap; fire size and how much of the time the flames actually touch the tubes; and, on the big units, how much of the fire’s heat the steel is already taking.
How your fire, wood and fireplace shape the result
Here’s what moves the number most in your house, roughly from biggest to smallest:
- Doors open, and the right fit. Every model in this table is meant to run with the fireplace doors open. Running one behind closed glass doors isn’t how it’s meant to be used, and our estimates don’t apply. The heater also has to fit through your fireplace opening and sit in the fire.
- Wood moisture. Wet or green wood (30%+ moisture) spends a lot of its heat boiling off water, burns cooler, smokes more, and can easily halve what you get. Seasoned wood is under 20%. A moisture meter is a cheap friend to the fire.
- Fire size and how you tend it. A small fire, or one burning down to coals, sits at the low end. A full, well-fed fire with a good coal bed sits at the high end. Adding a split or two before the fire dies keeps you near typical.
- Wood species and load size. Dense hardwoods (oak, hickory, maple) give a longer, steadier fire per load than pine or poplar. Pine burns hot and fast, so you get bursts of heat with more tending. Bigger loads mean more heat, up to what the fireplace can draw safely.
- Firebox shape and how close the heater sits to the fire. The tubes need to be in and around the flames. A fire that’s set back, built off to one side, or too short to reach the tubes gives less. Tapered fireboxes, wider at the front, are why we make the TGR. The heater should fill the firebox and sit under and behind the fire.
- Damper, draft and chimney height. A tall chimney or a wide-open damper pulls hard. That brings more air through the fire and more heat up the flue, and it also pulls warm room air out of the house. Close the damper as far as it’ll go without smoke spilling into the room. Very weak draft can mean a smoky, lazy fire.
- Ash bed. A thin bed of ash, about an inch, holds coals and keeps the fire hot under the tubes. A deep pile buries the bottom of the tubes and smothers airflow under the fire. Empty it regularly; a lift-out ash tray helps.
- Fan speed. More air means more heat delivered, at a lower outlet temperature. Turning the fan down gives hotter air but less total heat. A clogged or dusty intake costs output. Fans also vary a little from batch to batch.
- Warm-up and cool-down. The steel takes several minutes to come up to temperature after the fire takes off, and heavier models like the HTH5 take a bit longer. They also keep blowing warm air longer as the fire dies down. Over a whole evening it evens out.
- The room and the house. The same 10,000 BTU/h feels very different in a small, tight den than in a drafty great room with a high ceiling. Outdoor temperature, insulation, open floor plans and whether another heater is also running all change how warm it feels. We assume 65–70 °F room air. Colder air coming in picks up a little more heat.
Use the numbers to compare sizes and to set expectations. About 12,000 BTU/h on a normal fire is a fair, physics-based answer for a 20” GR. Dry, seasoned wood, a well-tended fire with a good coal bed, and the damper set right will land you nearer typical or the high end. Wet wood and a small, settling fire will land you nearer the low end, sometimes about half the typical figure. That assumes doors open and a heater that fits your opening.
A few key sizes
BTU/h and kW are both rates: how much heat the heater is delivering at a given moment. One kW running for an hour is one kWh of heat.
| Model / PLU | Family | Tubes | Typical BTU/h | Range BTU/h | Typical kW | Range kW | Page |
|---|---|---|---|---|---|---|---|
| 8HTH14D | HTH | 1 | 2,600 | 900–4,100 | 0.8 | 0.3–1.2 | link |
| 20HTH20D | HTH | 1 | 4,300 | 1,500–6,500 | 1.3 | 0.5–1.9 | link |
| 24HTH24D | HTH | 1 | 5,100 | 1,800–7,500 | 1.5 | 0.5–2.2 | link |
| 8HTH514D | HTH5 | 1 | 3,200 | 1,100–5,000 | 0.9 | 0.3–1.5 | link |
| 20HTH520D | HTH5 | 1 | 5,200 | 1,800–7,900 | 1.5 | 0.5–2.3 | link |
| 24HTH524D | HTH5 | 1 | 6,200 | 2,200–9,100 | 1.8 | 0.6–2.7 | link |
| 14GR14TD | GR | 7 | 7,800 | 3,000–10,700 | 2.3 | 0.9–3.1 | link |
| 20GR16TD | GR | 10 | 11,800 | 4,600–15,200 | 3.5 | 1.4–4.4 | link |
| 36GR24TD | GR | 18 | 25,200 | 10,600–29,300 | 7.4 | 3.1–8.6 | link |
| 14TGR14TD | TGR | 7 | 7,800 | 3,000–10,700 | 2.3 | 0.9–3.1 | link |
| 24TGR20TD | TGR | 12 | 15,600 | 6,300–18,600 | 4.6 | 1.9–5.5 | link |
| 36TGR24TD | TGR | 18 | 25,200 | 10,600–29,300 | 7.4 | 3.1–8.6 | link |
| 14DGR14TD | DGR | 13 | 10,500 | 4,000–15,800 | 3.1 | 1.2–4.6 | link |
| 20DGR16TD | DGR | 19 | 16,600 | 6,200–25,100 | 4.8 | 1.8–7.4 | link |
| 36DGR24TD | DGR | 35 | 34,200 | 13,900–45,300 | 10.0 | 4.1–13.3 | link |
The full list of 107 sizes, keyed by model and PLU, is at the end of this article. Your results vary with fire size, wood, draft, spacing, and fan speed; figures are estimates, not test results.
Who we are, and a note if you weld
Every heater is built in Texas, and we’ve been family operated since 2000. The default finish is seasoned steel, like a cast iron pan: it darkens with use and looks right at home in a firebox.
If you’ve got a welder and metalworking skills, see how the DIY kit works on our DIY kit page. The Q, RC and DS lines are now eligible, along with the HTH and the grate heaters already on the list.
Full reference table (all 107 sizes)
Estimated fan-on output for every live GR, TGR, DGR, HTH and HTH5 size in the current estimate table. Typical is a normal three-log fire. The range is a small or settling fire to a big hot fire. kW is the same heat, in kilowatts.
| Model / PLU | Family | Tubes | Typical BTU/h | Range BTU/h | Typical kW | Range kW | Page |
|---|---|---|---|---|---|---|---|
| 14GR14TD | GR | 7 | 7,800 | 3,000–10,700 | 2.29 | 0.88–3.14 | link |
| 14GR16TD | GR | 7 | 8,600 | 3,300–11,300 | 2.51 | 0.96–3.31 | link |
| 14GR20TD | GR | 7 | 9,700 | 3,800–12,100 | 2.85 | 1.12–3.55 | link |
| 14GR24TD | GR | 7 | 10,500 | 4,300–12,500 | 3.07 | 1.27–3.66 | link |
| 16GR14TD | GR | 8 | 8,800 | 3,400–12,000 | 2.59 | 1.0–3.51 | link |
| 16GR16TD | GR | 8 | 9,700 | 3,700–12,600 | 2.84 | 1.09–3.7 | link |
| 16GR20TD | GR | 8 | 11,000 | 4,300–13,600 | 3.21 | 1.27–3.98 | link |
| 16GR24TD | GR | 8 | 11,800 | 4,900–14,000 | 3.46 | 1.44–4.09 | link |
| 20GR14TD | GR | 10 | 10,800 | 4,200–14,400 | 3.17 | 1.24–4.21 | link |
| 20GR16TD | GR | 10 | 11,800 | 4,600–15,200 | 3.47 | 1.35–4.44 | link |
| 20GR20TD | GR | 10 | 13,400 | 5,300–16,200 | 3.92 | 1.56–4.75 | link |
| 20GR24TD | GR | 10 | 14,300 | 6,000–16,700 | 4.2 | 1.77–4.91 | link |
| 24GR14TD | GR | 12 | 12,700 | 5,000–16,500 | 3.72 | 1.47–4.84 | link |
| 24GR16TD | GR | 12 | 13,900 | 5,400–17,400 | 4.07 | 1.6–5.1 | link |
| 24GR20TD | GR | 12 | 15,600 | 6,300–18,600 | 4.58 | 1.85–5.45 | link |
| 24GR24TD | GR | 12 | 16,600 | 7,200–19,400 | 4.86 | 2.1–5.68 | link |
| 30GR14TD | GR | 15 | 16,200 | 6,300–22,300 | 4.75 | 1.84–6.52 | link |
| 30GR16TD | GR | 15 | 17,700 | 6,800–23,400 | 5.19 | 2.0–6.87 | link |
| 30GR20TD | GR | 15 | 20,000 | 7,900–25,100 | 5.85 | 2.32–7.36 | link |
| 30GR24TD | GR | 15 | 21,500 | 8,900–25,800 | 6.29 | 2.62–7.57 | link |
| 36GR14TD | GR | 18 | 19,100 | 7,500–25,400 | 5.6 | 2.19–7.44 | link |
| 36GR16TD | GR | 18 | 20,900 | 8,100–26,700 | 6.12 | 2.37–7.83 | link |
| 36GR20TD | GR | 18 | 23,500 | 9,400–28,500 | 6.89 | 2.75–8.36 | link |
| 36GR24TD | GR | 18 | 25,200 | 10,600–29,300 | 7.37 | 3.1–8.6 | link |
| 14TGR14TD | TGR | 7 | 7,800 | 3,000–10,700 | 2.29 | 0.88–3.14 | link |
| 14TGR16TD | TGR | 7 | 8,600 | 3,300–11,300 | 2.51 | 0.96–3.31 | link |
| 14TGR20TD | TGR | 7 | 9,700 | 3,800–12,100 | 2.85 | 1.12–3.55 | link |
| 14TGR24TD | TGR | 7 | 10,500 | 4,300–12,500 | 3.07 | 1.27–3.66 | link |
| 16TGR14TD | TGR | 8 | 8,800 | 3,400–12,000 | 2.59 | 1.0–3.51 | link |
| 16TGR16TD | TGR | 8 | 9,700 | 3,700–12,600 | 2.84 | 1.09–3.7 | link |
| 16TGR20TD | TGR | 8 | 11,000 | 4,300–13,600 | 3.21 | 1.27–3.98 | link |
| 16TGR24TD | TGR | 8 | 11,800 | 4,900–14,000 | 3.46 | 1.44–4.09 | link |
| 20TGR14TD | TGR | 10 | 10,800 | 4,200–14,400 | 3.17 | 1.24–4.21 | link |
| 20TGR16TD | TGR | 10 | 11,800 | 4,600–15,200 | 3.47 | 1.35–4.44 | link |
| 20TGR20TD | TGR | 10 | 13,400 | 5,300–16,200 | 3.92 | 1.56–4.75 | link |
| 20TGR24TD | TGR | 10 | 14,300 | 6,000–16,700 | 4.2 | 1.77–4.91 | link |
| 24TGR14TD | TGR | 12 | 12,700 | 5,000–16,500 | 3.72 | 1.47–4.84 | link |
| 24TGR16TD | TGR | 12 | 13,900 | 5,400–17,400 | 4.07 | 1.6–5.1 | link |
| 24TGR20TD | TGR | 12 | 15,600 | 6,300–18,600 | 4.58 | 1.85–5.45 | link |
| 24TGR24TD | TGR | 12 | 16,600 | 7,200–19,400 | 4.86 | 2.1–5.68 | link |
| 30TGR14TD | TGR | 15 | 16,200 | 6,300–22,300 | 4.75 | 1.84–6.52 | link |
| 30TGR16TD | TGR | 15 | 17,700 | 6,800–23,400 | 5.19 | 2.0–6.87 | link |
| 30TGR20TD | TGR | 15 | 20,000 | 7,900–25,100 | 5.85 | 2.32–7.36 | link |
| 30TGR24TD | TGR | 15 | 21,500 | 8,900–25,800 | 6.29 | 2.62–7.57 | link |
| 36TGR14TD | TGR | 18 | 19,100 | 7,500–25,400 | 5.6 | 2.19–7.44 | link |
| 36TGR16TD | TGR | 18 | 20,900 | 8,100–26,700 | 6.12 | 2.37–7.83 | link |
| 36TGR20TD | TGR | 18 | 23,500 | 9,400–28,500 | 6.89 | 2.75–8.36 | link |
| 36TGR24TD | TGR | 18 | 25,200 | 10,600–29,300 | 7.37 | 3.1–8.6 | link |
| 14DGR14TD | DGR | 13 | 10,500 | 4,000–15,800 | 3.08 | 1.17–4.63 | link |
| 14DGR16TD | DGR | 13 | 11,500 | 4,300–16,600 | 3.36 | 1.27–4.87 | link |
| 14DGR20TD | DGR | 13 | 12,900 | 5,000–17,700 | 3.79 | 1.47–5.19 | link |
| 14DGR24TD | DGR | 13 | 13,900 | 5,600–18,400 | 4.07 | 1.65–5.4 | link |
| 16DGR14TD | DGR | 15 | 11,900 | 4,600–17,400 | 3.48 | 1.34–5.1 | link |
| 16DGR16TD | DGR | 15 | 13,000 | 5,000–18,300 | 3.8 | 1.45–5.36 | link |
| 16DGR20TD | DGR | 15 | 14,600 | 5,700–19,500 | 4.27 | 1.67–5.73 | link |
| 16DGR24TD | DGR | 15 | 15,600 | 6,400–20,400 | 4.58 | 1.87–5.99 | link |
| 20DGR16TD | DGR | 19 | 16,600 | 6,200–25,100 | 4.85 | 1.83–7.36 | link |
| 20DGR20TD | DGR | 19 | 18,600 | 7,200–26,800 | 5.45 | 2.1–7.84 | link |
| 20DGR24TD | DGR | 19 | 20,000 | 8,000–27,500 | 5.86 | 2.35–8.07 | link |
| 24DGR16TD | DGR | 23 | 19,600 | 7,400–29,100 | 5.74 | 2.18–8.54 | link |
| 24DGR20TD | DGR | 23 | 21,900 | 8,500–30,900 | 6.42 | 2.49–9.07 | link |
| 24DGR24TD | DGR | 23 | 23,500 | 9,500–31,900 | 6.88 | 2.79–9.36 | link |
| 30DGR20TD | DGR | 29 | 27,300 | 10,600–39,500 | 7.99 | 3.1–11.58 | link |
| 30DGR24TD | DGR | 29 | 29,200 | 11,800–40,600 | 8.56 | 3.45–11.89 | link |
| 36DGR16TD | DGR | 35 | 28,800 | 11,000–41,600 | 8.44 | 3.23–12.18 | link |
| 36DGR20TD | DGR | 35 | 32,100 | 12,500–43,900 | 9.4 | 3.67–12.88 | link |
| 36DGR24TD | DGR | 35 | 34,200 | 13,900–45,300 | 10.03 | 4.08–13.27 | link |
| 8HTH14D | HTH | 1 | 2,600 | 900–4,100 | 0.77 | 0.26–1.2 | link |
| 8HTH16D | HTH | 1 | 2,900 | 1,000–4,500 | 0.86 | 0.3–1.32 | link |
| 8HTH20D | HTH | 1 | 3,500 | 1,200–5,300 | 1.03 | 0.36–1.57 | link |
| 8HTH24D | HTH | 1 | 4,100 | 1,400–6,100 | 1.19 | 0.42–1.79 | link |
| 14HTH14D | HTH | 1 | 3,100 | 1,100–4,700 | 0.9 | 0.31–1.39 | link |
| 14HTH16D | HTH | 1 | 3,400 | 1,200–5,200 | 0.99 | 0.34–1.51 | link |
| 14HTH20D | HTH | 1 | 3,900 | 1,400–5,900 | 1.15 | 0.4–1.74 | link |
| 14HTH24D | HTH | 1 | 4,500 | 1,600–6,700 | 1.31 | 0.46–1.95 | link |
| 16HTH14D | HTH | 1 | 3,200 | 1,100–4,900 | 0.94 | 0.33–1.45 | link |
| 16HTH16D | HTH | 1 | 3,500 | 1,200–5,400 | 1.03 | 0.36–1.57 | link |
| 16HTH20D | HTH | 1 | 4,100 | 1,400–6,100 | 1.19 | 0.42–1.8 | link |
| 16HTH24D | HTH | 1 | 4,600 | 1,600–6,800 | 1.35 | 0.48–2.01 | link |
| 20HTH14D | HTH | 1 | 3,500 | 1,200–5,400 | 1.03 | 0.36–1.57 | link |
| 20HTH16D | HTH | 1 | 3,800 | 1,300–5,800 | 1.11 | 0.39–1.69 | link |
| 20HTH20D | HTH | 1 | 4,300 | 1,500–6,500 | 1.27 | 0.45–1.91 | link |
| 20HTH24D | HTH | 1 | 4,900 | 1,700–7,200 | 1.43 | 0.51–2.11 | link |
| 24HTH14D | HTH | 1 | 3,800 | 1,300–5,800 | 1.11 | 0.39–1.69 | link |
| 24HTH16D | HTH | 1 | 4,100 | 1,400–6,100 | 1.19 | 0.42–1.8 | link |
| 24HTH20D | HTH | 1 | 4,600 | 1,600–6,900 | 1.35 | 0.48–2.01 | link |
| 24HTH24D | HTH | 1 | 5,100 | 1,800–7,500 | 1.5 | 0.54–2.21 | link |
| 8HTH514D | HTH5 | 1 | 3,200 | 1,100–5,000 | 0.93 | 0.32–1.46 | link |
| 8HTH516D | HTH5 | 1 | 3,500 | 1,200–5,500 | 1.04 | 0.36–1.62 | link |
| 8HTH520D | HTH5 | 1 | 4,200 | 1,500–6,500 | 1.24 | 0.43–1.91 | link |
| 8HTH524D | HTH5 | 1 | 4,900 | 1,700–7,400 | 1.44 | 0.5–2.18 | link |
| 14HTH514D | HTH5 | 1 | 3,700 | 1,300–5,800 | 1.09 | 0.38–1.69 | link |
| 14HTH516D | HTH5 | 1 | 4,100 | 1,400–6,300 | 1.19 | 0.41–1.84 | link |
| 14HTH520D | HTH5 | 1 | 4,700 | 1,700–7,200 | 1.39 | 0.49–2.12 | link |
| 14HTH524D | HTH5 | 1 | 5,400 | 1,900–8,100 | 1.58 | 0.56–2.38 | link |
| 16HTH514D | HTH5 | 1 | 3,900 | 1,300–6,000 | 1.14 | 0.39–1.77 | link |
| 16HTH516D | HTH5 | 1 | 4,200 | 1,500–6,500 | 1.24 | 0.43–1.91 | link |
| 16HTH520D | HTH5 | 1 | 4,900 | 1,700–7,500 | 1.44 | 0.5–2.19 | link |
| 16HTH524D | HTH5 | 1 | 5,500 | 2,000–8,300 | 1.63 | 0.57–2.44 | link |
| 20HTH514D | HTH5 | 1 | 4,200 | 1,500–6,500 | 1.24 | 0.43–1.91 | link |
| 20HTH516D | HTH5 | 1 | 4,600 | 1,600–7,000 | 1.34 | 0.47–2.05 | link |
| 20HTH520D | HTH5 | 1 | 5,200 | 1,800–7,900 | 1.53 | 0.54–2.32 | link |
| 20HTH524D | HTH5 | 1 | 5,900 | 2,100–8,700 | 1.72 | 0.61–2.56 | link |
| 24HTH514D | HTH5 | 1 | 4,600 | 1,600–7,000 | 1.34 | 0.47–2.06 | link |
| 24HTH516D | HTH5 | 1 | 4,900 | 1,700–7,500 | 1.44 | 0.5–2.19 | link |
| 24HTH520D | HTH5 | 1 | 5,600 | 2,000–8,300 | 1.63 | 0.57–2.44 | link |
| 24HTH524D | HTH5 | 1 | 6,200 | 2,200–9,100 | 1.81 | 0.64–2.68 | link |
Your results vary with fire size, wood, draft, spacing, and fan speed; figures are estimates, not test results.
Sources
- US EPA Burn Wise, Choosing the Right Fireplace or Fireplace Retrofit Device and Energy Efficiency and Your Wood-Burning Appliance (program archive, 2025).
- University of Illinois Extension, Firewood: Stoves and Fireplaces (open fireplaces around 10% efficient).
- US EPA-600/2-80-042b, Source Assessment: Residential Combustion of Wood (1980).
- USDA Forest Products Laboratory, Wood Handbook, and fuel-value data (about 8,600 BTU per pound of oven-dry wood). Utah State University Extension, Wood Heating.
- Houck & Tiegs (OMNI-Test Laboratories), Residential Wood Combustion, WESTAR (typical fireplace burn rates and efficiency).
- Standard heat-transfer engineering references for radiation, convection, conduction and heat-exchanger effectiveness.
- Fan manufacturer specifications for the 120 mm, 110 cfm AC fan used on our GR, TGR and DGR.